Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the acf domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/hansaeng/domains/dev.hansa-engineering.se/wp-includes/functions.php on line 6260

Deprecated: Function seems_utf8 is deprecated since version 6.9.0! Use wp_is_valid_utf8() instead. in /home/hansaeng/domains/dev.hansa-engineering.se/wp-includes/functions.php on line 6260
Are there any specific requirements regarding separation/removal efficiency? | Hansa Engineering

Droplet separation

Are there any specific requirements regarding separation/removal efficiency?

Separation or removal efficiency targets may be set by statutory emission requirements or a need to reduce a certain amount of contaminants in order to avoid corrosion and other damage downstream in the process. In some processes, droplet separators are used to reuse valuable substances and product.

Knowledge bank Drip trapping

Separation efficiency specifies the degree of liquid and particles the droplet separator removes from the gas flow. Separation efficiency is calculated using a number of variables, including type of droplet separator (mist eliminator), gas and liquid density, gas flow velocity and amount of liquid.

An increased gas flow rate leads to increased separation efficiency, but it also means an increase in pressure drop. It is important to consider the trade-off between level of separation efficiency and total operating cost.